Section 3: Mechanical Installation
November 2014
3.4.5
Tri-Clamp™ tank connection
Figure 3-22. Mounting the Rosemount 5400 using a Tri-Clamp
A
B
C
D
1.
2.
3.
4.
5.
6.
40
Place a gasket on top of the tank flange.
Lower the transmitter and antenna into the tank.
Fasten the Tri-Clamp to the tank with a clamp.
To rotate the transmitter housing, loosen the nut.
Rotate the transmitter housing so the cable entries / display face the desired direction.
Tighten the nut.
A. Nut
B. Rod antenna
C. Gasket
D. Tank connection
E. Tri-Clamp
F. Clamp
E