Section 5: Basic Configuration/Start-up
November 2014
5.3.4

Volume configuration

For volume calculations, choose one of the standard tank shapes or the strapping option. Select
None if volume calculation is not used. For the standard tanks, a Volume Offset parameter can
be specified which can be used for a non-zero volume that corresponds to the zero level. This
may be useful, for example, if the user wants to include the product volume below the zero level.
Volume calculation is performed by using a predefined tank shape or a strapping table. One of
the following standard tank shapes can be chosen:
The following parameters must be entered for a standard tank shape:
78
Sphere
Vertical cylinder
Horizontal cylinder
Vertical bullet
Horizontal bullet
Tank diameter
Tank height (not for spherical tanks)
Volume offset
Reference Manual