Figure 3-2. Mounting in Still-Pipe
Figure 3-3. Multiple Rosemount 5400 Series Transmitters in the Same Tank
Mechanical Installation
A metal still-pipe can be used to avoid disturbing objects, turbulence, and foam (G)
(G)
The walls in non-metallic tanks are invisible to the radar signal, so nearby objects
outside of the tank may be detected
Choose the largest possible antenna diameter for installation. A larger antenna
concentrates the radar beam, will be less susceptible to obstruction interference, and
assures maximum antenna gain
Multiple Rosemount 5400 Series transmitters can be used in the same tank without
interfering with each other (H)