14.1 Hardware Installation

14.1.1 Initial Checks

Upon receiving your equipment, carefully inspect all shipping containers for
damage. If any part of the system is damaged, notify the carrier immediately. The
damaged shipping container should be saved as evidence for inspection by
carrier.
As the consignee, it is your responsibility to register a claim with the carrier for
damage incurred during shipment. GE Automation & Controls will fully cooperate
with you, however, should such action be necessary.
After unpacking the equipment, record all serial numbers. Serial numbers are
required if you should need to contact Customer Care during the warranty period.
All shipping containers and all packing material should be saved should it be
necessary to transport or ship any part of the system.
Verify that all components of the system have been received and that they agree
with your order. If the system received does not agree with your order, contact
Customer Care.

14.1.2 Installation Location

As shipped, the CPE100 is intended for mounting on a DIN rail. An optional panel-
mount adaptor is also available with part number (ICMFAACC001-AA). If panel-
mounting is required, replace the DIN-rail adaptor with the panel-mount adaptor
using the screws supplied with that adaptor. Both adaptors attach to the rear of
the CPE100 chassis using four Torx M3 screws. Torque newly-installed screws to
5.3 in-Ibs (0.6 Nm) if installing a new adaptor plate.
Thermal Requirements:
When mounting the CPE100, allow a minimum clearance of 50mm on the left &
right side of the unit and a minimum clearance of 100mm on the top & bottom
sides.
Instructions to mount the CPE100 on a DIN Rail:
The CPE100 snaps easily onto the DIN rail. No additional tools are required.
(1) Incline the unit so that the upper hooks of the DIN rail adaptor engage with the
upper edge of the DIN rail.
(2) Press on the lower part of the unit until you hear a click. The click indicates that
the lower hooks of the DIN rail adaptor have engaged with the lower edge of the
DIN rail.
If you need any technical help, please contact Technical Support. For phone
numbers and email addresses, refer to the back cover of this Guide.