GE RSTi-EP User Manual page 208

Standalone 1ghz programmable controller
Hide thumbs Also See for RSTi-EP:
Table of Contents

Advertisement

Byte
Format
IB0 ... IB3
Double word
IB4 ... IB7
Double word
IB8 ... IB11
Double word
IB12 ... IB15
Double word
IB16
Word
IB17
IB18
Word
IB19
Internal process data mapping with data format Standard. Depending on the fieldbus specification and the data format of
the communicating fieldbus components the bytes and/or words can be reversed during data transfer.
Byte
Format
QB0 ... QB3
Double word
QB4 ... QB7
Double word
QB8
Word
QB9
QB10
Word
QB11
Internal process data mapping with data format Standard. Depending on the fieldbus specification and the data format of
the communicating fieldbus components the bytes and/or words can be reversed during data transfer.
GFK-2958E
Process Data
Name
Bit
Counter 0:
Counter value
Counter 1:
Counter value
Counter 0:
Counter status
Counter 1:
Counter status
IX16.0
... 16.7
Channel 0:
IX17.0
Status
IX17.1
... 17.7
IX18.0
... 18.7
Channel 1:
IX19.0
Status
IX19.1
... 19.7
Process Data
Bit
Name
Channel 0:
Measurement
cycle period
Channel 1:
Measurement
cycle period
QX8.0 -
QX8.7
Channel 0:
QX9.0
Control word
QX9.1
QX9.2 -
9.7
QX10.0
- X10.7
QX11.0
Channel 1:
Control word
QX11.1
QX11.2
- 11.7
RSTi-EP User Manual
Chapter 5 Detailed Descriptions of I/O Modules
Inputs EP-5212
Function when active
Remark
Channel 0: Currently measured value
of period duration multiplied by 125 ns
results in the current period duration
in μs
Channel 0: Number of rising edges
within the current measurement cycle
Channel 1: Currently measured value
of period duration multiplied by 125 ns
results in the current period duration
in μs
Channel 1: Number of rising edges
within the current measurement cycle
reserved
Measurement active
reserved
reserved
Measurement active
reserved
Outputs EP-5212
Function when
Remark
edge 0-1
Channel 0: Preset value of the
measurement cycle period (23 Bit)
Channel 1: Preset value of the
measurement cycle period (23 Bit)
reserved
Measurement start
Measurement stop
reserved
reserved
Measurement start
Measurement stop
reserved
204

Advertisement

Table of Contents
loading

This manual is also suitable for:

Gfk-2958e

Table of Contents