Automatic Maintenance Function; Setting The Refreshing Intervals; Setting The Cleaning Intervals And Type - MIMAKI UCJV300-75 Operation Manual

Ucjv300 series; ucjv150 series uv inkjet printer cutter
Hide thumbs Also See for UCJV300-75:
Table of Contents

Advertisement

Automatic Mainte-
nance Function
To use this machine comfortably, you can set various
maintenances to be performed automatically.
Here, set performing intervals of various automatic
maintenances.
You can prevent troubles such as ink clogging by
performing automatic maintenance periodically
(Auto maintenance function).
For the auto maintenance functions, the following items
can be set:
• When you perform maintenance manually, after
manual maintenance is completed and when time
set with the automatic maintenance function has
passed, maintenance starts automatically.
Function
name
The interval between each refreshing
REFRESH
operation is set.
CLEANING
The interval between each cleaning operation
(INTERVAL)
is set.
CLEANING
The cleaning type is set.
(TYPE)
• If the "Check waste ink" warning message is dis-
played, the operation set in the auto maintenance
function is not carried out. Perform the operations
of P.5-19 if required.
• When the power switch on the front of the machine
is turned off, check the waste ink tank.

Setting the Refreshing Intervals

The interval between each operation of ejecting a small
amount of ink from the nozzles to prevent nozzle clogging
is set.
1
Press the
press the
• MAINTENANCE MENU will be displayed.
2
Press
to select "AUTO
MAINTENANCE", and press the
key.
3
Press
to select "REFRESH", and
press the
4
Press
to set the refreshing
interval, and press the
• Set value : The set value will differ according to
the ink type being used.
5
Press the
end the setting.
Descriptions
and
(MENU)
key.
key.
key.
key several times to
Setting the Cleaning Intervals and
Type
The cleaning type and the interval between each cleaning
operation are set.
1
Press the
press the
• MAINTENANCE MENU will be displayed.
2
Press
to select "AUTO
MAINTENANCE", and press the
key.
3
Press
several times to select
"Interval" or "Type", and press the
key.
4
Press
to select the setting item,
and press the
• Set value:
• Set value of type: SOFT/ NORMAL/ HARD
5
Press the
end the setting.
Chapter 5 Maintenance
and
(MENU)
key.
key.
The
set
value
will
differ
according to the ink type being
used.
key several times to
5
2
5-15

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ucjv300-160Ucjv300-107Ucjv300-130Ucjv150-160