Chapter 6 Troubleshooting
Message
ERROR 505
MEDIA JAM
ERROR 519
NEGATIVE P.SENSOR
ERROR 522
CUT HOME POSITION
ERROR 525
WRONG IONIZER
ERROR 526
IONIZER ION LEVEL
ERROR 527
IONIZER CONDITION
ERROR 528
PUMP MOTOR SENSOR
ERROR 549
LEnc. Count DIO
ERROR 608
WRONG INK IC
ERROR 61A
InkOverflow
ERROR 61B
SUPPLY INK
ERROR 61D
NEGATIVE P. NotEnough,
ERROR 61E
NEGATIVE P. OVER,
ERROR 620
POSITIVE P.NotEnough,
ERROR 621
POSITIVE P.OVER,
ERROR 627
ERROR627 INK BOTTLE SET
6-10
Cause
MEDIA JAM SENSOR reacted.
Automatic recognition of negative pres-
sure sensor failed.
Cutter head could not be moved due to
connection failure between the cutter
head and the connecting unit.
The internal circuit of the ionizer was
broken or abnormal discharge occurred.
Due to contamination and abrasion of
the electrode needle, the ion generation
amount is reduced.
When ions are absorbed by the sur-
rounding metal, the static elimination
capability is affected by instability of
installation environment (temperature,
humidity, surrounding metals, etc.).
Pump sensor detection error.
The linear scale wiring to the DIO PCB is
disconnected.
The IC chip cannot be correctly read.
The float sensor of the subtank detected
Limit.
Failed to supply ink to the sub tank
It became impossible to maintain the
negative pressure within the proper
range (plus side)
It became impossible to maintain the
negative pressure within the proper
range (minus side)
It became impossible to maintain the
positive pressure within the proper range
(plus side)
IC chip can not be read for a certain
time.
Measures
• Remove the contacted media and reset it.
• Open the cover and check whether there is
any obstacle in the movement of the car-
riage.
• Turn off the power on the machine and turn it
on after a while.
When displaying again, contact your local
distributor, our sales office, or service center.
• Clean the electrode needle by looking at the
ionizer instruction manual.
• If the symptoms do not improve, replace the
corresponding static electrode needle.
• Make sure there are no conductors or other
static eliminator near the ionizer.
• Keep away from conductors and static elimi-
nators if they are nearby.
• Turn off the power on the machine and turn it
on after a while.
When displaying again, contact your local
distributor, our sales office, or service center.
• Make sure that the IC chip is correctly
inserted.
• Reinsert the bottle.
• Turn off the power on the machine and turn it
on after a while.
When displaying again, contact your local
distributor, our sales office, or service center.
• Perform "Maintenance" "Overflow Mainte-
nance".
When displaying again, contact your local
distributor, our sales office, or service center.
• Turn off the power on the machine and turn it
on after a while.
When displaying again, contact your local
distributor, our sales office, or service center.
• Make sure that the bottle is correctly
inserted.
• Reinsert the bottle.
• Turn off the power on the machine and turn it
on after a while.
When displaying again, contact your local
distributor, our sales office, or service center.