3: When values are set for a channel with the user range 1 of 2 to 10V as follows:
Ex.
• "CH
Scaling enable/disable setting": "0: Enable"
• "CH
Scaling upper limit value": 8000
• "CH
Scaling lower limit value": 2000
The digital values and scale-converted digital values are as follows:
Analog output voltage (V)
10V
2V
0V
-12288
-12000
-4000
Digital value
-4000
-1000
2000
5000
8000
-6V
0
12000
12287
Scaling lower limit
Scaling upper limit
value: 2000
value: 8000
Digital value after scale
conversion
-12000
-6000
0
6000
12000
CHAPTER 8 FUNCTION
Scale converted digital value
Digital value
Analog output voltage (V)
-6
-2
10
8
2
6
83