D/I Mux III User's Manual
Setting Communications in Terminal Mode With
Alarm Reporting Off
Figure J-3 depicts the Set report Options (SO) command sequence screen, resulting in communications
in terminal mode with alarm reporting turned off.
Selecting option C under Communication Configuration sets the communications mode. Then, selecting
option T specifies that communications will be controlled by a terminal versus MML. The next option to
appear is the Alarm Reporting Mode.
The choices for alarm reporting mode include T) Terminal Alarm Reporting, E) Enable Modem Dial-
out, or O) Off. Option O turns off alarm reporting. The terminal will still detect and record alarms, but
will not interrupt the operation of the Common Control Unit (CCU).
Once all selections are made, Current Mode displays again, reflecting the selection.

Feature Group 6.0/6.2 Screen Changes

The 6.0/6.2 Feature Group COMM Mode selections were labeled
1) Terminal and 2) MML. Options, however, were the same as found in current Feature Group.
The 6.0/6.2 Feature Group Alarm Reporting Mode selections were limited to T) Terminal, and O)
Off, and did not allow alarm dial-out in terminal communications mode.
The 6.0/6.2 Feature Group Current Mode with no alarm reporting was labeled simply OFF.