Interactive Technologies, Inc.
Preset
Syntax
Command
Preset <preset number> On
Preset <preset number> Off
Preset <preset number> At <value>
Preset <preset number> Toggle <value>
•
<preset number>
◦ Any whole number from
•
<value>
◦ A percentage from
by the
sign.
%
◦ A decimal number from
proceeded with a
◦ A hexadecimal number from
must be proceeded with a
◦
(Full) or
FL
◦
can be used as a shortcut that means
Off
Abbreviation
PR
to
1
999
to 100. When specifying percentages, the value can optionally be followed
0
to #255. When specifying decimal numbers, the value must be
#0
sign.
#
to $FF. When specifying hexadecimal numbers, the value
$00
sign.
$
can be used as a shortcut that means
On
Description
Activates the specified preset in the current
zone
Deactivates the specified preset in the
current zone
Activates the specified preset in the current
zone at the given intensity level
Activates or deactivates the specified
preset in the current zone at the given
intensity level
100%
0%
CueServer 2 User's Manual - 18.5.18
Return Value
The preset
number
activated
The preset
number
deactivated
The preset
number
activated
The preset
number
toggled
Page 217 of 429
Need help?