Interactive Technologies CueServer 2 User Manual page 165

Table of Contents

Advertisement

Interactive Technologies, Inc.
Determining Which Outputs Are Selected
The question mark
can be used to ask what the current selection is. A selection string will be returned,
?
which will consist of a single number (like 3) or a range (like 5>7+9), or if no outputs are selected,
returned.
Examples
Output 1
Selects output 1. Future action commands will be directed towards output 1. Also returns 0, or
indicate if the output is currently off or on.
Output 1>5 On
Turns on outputs 1 thru 5.
Output 1>3+5>8 Off
Turns off outputs 1 through 3 and 5 through 8.
Output 7 At 50
Sets the level of output 7 to 50% (any non-zero level turns an output on).
Output ?
Returns the current output selection in the format of a single number like 3, or a range like 5>7+9.
See Also
Selection Operators
• At, Off,
On
CueServer 2 User's Manual - 18.5.18