Test: Manual_Activate - Siemens MXL-IQ Operation, Installation, And Maintenance Manual

Table of Contents

Advertisement

001 YES NO
Press NEXT and the System displays:
002 YES NO
The System flashes the currently active
summarize selection for the module
address. The operator may then press the
right or left arrow keys to highlight either
YES or NO and then press the ENTER key
to accept and program the selection. When
ENTER is pressed, the System scrolls to
the next installed module address. The Up
arrow key terminates the Select_Mods
mode.
All Select_Mods selections remain intact
until the System is turned off, even if
summarize mode is toggled.
• One trouble is posted per module
address, regardless of how many
troubles are detected at that module
address.
• A trouble is not posted unless at least
one trouble is detected at that module
address.
• The trouble report is consistent with
existing MXL-IQ trouble messages and
the text reads Troubles summarized.
• The MXL-IQ only reports TRBL-INs
when summary mode is enabled at an
address.
• Alarm, supervisory, security, and status
event reporting are not effected.
Modules which are NOT selected for
summary report their troubles as usual,
even if summary mode is turned on for
other module addresses.
When a module address is summarized,
individually occurring troubles are not
broadcast to XNET; the single Troubles
summarized trouble is broadcast to XNET.
The Troubles summarized trouble is
implemented as any other system trouble,
being logged to history, taking up one of the
300 trouble slots, and appearing in List
Troubles requests. All summarize selec-
tions are unaffected through RESET and
default to CSG-M setting at power up.
Test: Summarize - OFF
When Summarize OFF is selected, the
System annunciates the following trouble:
System Commissioning Mode TRBL OUT
and turns off the Partial System Disable
LED. Preexisting Troubles summarized
events remain and the System reverts to
normal trouble reporting and processing for
all new troubles.
Test: Summarize - ON
When Summarize ON is selected, the
System annunciates the following trouble:
System Commissioning Mode TRBL IN
and turns on the Partial System Disable
LED. The System displays one summarized
trouble for the total system.

Test: Manual_Activate

Use Test Manual_Activate to:
• Perform testing on input points and the
associated output logic expected when
the point is activated.
• Generate alarms and associated output
activations.
Select Manual_Activate and press ENTER.
The System asks you for a module number
and device number.
Type In Module & Device:
Type the three-digit module number and
three-digit device number using rhe numeric
keypad and press ENTER. Upon entering
the device address, the System performs as
follows based on the point type:
M
A
N
U
A
L
N I
P
U
T
P
O
N I
N
o
n I
p
t u
P
i o
t n
E
r r
r o
m
e
A
n
a
o l
g
S
m
o
k
e
S
s y
e t
m
D
e
e t
c
o t
s r
p
a l
c
e
d
e
s
a t
e t
v
a i
D
e
v
c i
e
h t
f i
a
n
a
c
u t
A
s s
o
c
a i
A
l l
O
h t
r e
n i
p
u
s t
S
s y
e t
m
c
o
m
m
a
n
s
n y
h t
e
i s
e z
l a
r a
m
n i
A
s s
o
c
a i
-
T
A
C
T
V I
A
T
O I
N
s s
a
g
. e
i
s s
u
e
s
c
o
m
m
a
n
d
o t
v
c i
e
n i
o t
h t
e
l a
r a
m
s
e
s n
i t i
y t i
a
d
u j
t s
m
e
. t n
e
n
e r
p
r o
s t
l a
r a
m
a
s
l a
l a
r a
m
o
c c
r u
e r
. d
e t
d
o
u
p t
u
s t
o f
o l l
. w
w
l i
n l
o
i t
s s
u
e
a
y n
d
o t
d
e
v
c i
, e
b
t u
w
l l i
h t
e
e r
p
o
t r
n i
g
f o
b
y
h t
e
d
e
v
c i
. e
e t
d
o
u
p t
u
s t
o f
o l l
. w
Operation
3-49