MECHANICAL INSTALLATION
The following unit is certified for use in hazardous areas/locations ATEX/IECEx II 3G Ex nA IIC T4 Gc or CSA Zone 2, Class
I Div. 2, and Class I (Zone 2). This enclosure can only be used as a remote unit as no controller option is available.

4.3 Installing Floor Standing Enclosures

The TPPR Controller can be mounted in a range of large powder coated steel floor mounted enclosures, either fully
enclosed or with or additional natural or forced ventilation.
All enclosures are approximately 2000 x 800 x 600 mm (without ventilation hood and lifting lugs)) and weigh >230 kg. See
the shipping note for accurate details.
Note: Optional air vents can be fitted to front or rear doors depending on whether front or rear cable access is used.
Users shall not allow the ventilation to become blocked or subjected to moisture ingress as this will void certification
Touchpoint Pro enclosures are heavy and unwieldy (refer to Specifications) and a single person lift is not
recommended. Before lifting the enclosure, consider and implement control measures to reduce the risk of injury.
It is the installer's responsibility to select the appropriate fixings while taking into account the structure of the
Due to their size and weight, floor mounted enclosures must stand on a minimum 100 mm thick purpose built plinth,
Part. No. 2400M2501_6
Figure 35.
Hazardous Area Wall Mounted Enclosure
and the warranty, and may cause irreparable damage.
Refer to local safety regulations.
mounting surface and the weight of the specific enclosure.
and must be securely fixed to either the plinth or wall.
Wall and plinth fixing bolts should be a minimum 8 mm dia. x 50 mm depth.
CAUTION
CAUTION
CAUTION
CAUTION
28
Touchpoint Pro
Technical Handbook