Commissioning (COMpact 5000R)

Turning on the PBX

Warning: Touching voltage-carrying conductors or telephone connections can cause
life-threatening electric shocks.
• Close the casing before you put the PBX into operation.
Note: If you have a USB memory stick with a configuration for automatic loading
(auconfig.cfg), insert it into the USB socket (USB host) of the CPU module before you switch
on the PBX. The configuration data stored on the USB memory stick will automatically be
saved to the PBX after switching on. The PBX restarts afterwards.
Requirements:
• PBX connected to earthing and casing closed
Connect the PBX to a freely accessible Schuko socket.
The Power and Status LEDs light up several seconds/minutes in
red and orange.
When the LEDs light up in green, the PBX is ready for operation.
Note: If the Power LED remains continuously lit in red, an error has occurred. Please contact
your dealer or the manufacturer directly.
Commissioning (COMpact 5000R)

Rack Mounting the PBX

Warning: Touching voltage-carrying conductors or telephone connections can cause
life-threatening electric shocks.
• Mount the PBX close of an earth wire (potential compensation bar of the house installation
or protective earth conductor). Connect the PBX's earth connection to the earth wire with
a connecting cable whose conductor diameter is at least 2.5 mm
Warning: Liquid entering the casing can cause life-threatening electric shocks or
damage or destroy the PBX.
• Only operate the PBX in closed, dry rooms.
Caution: Overheating can damage or destroy the system.
• Note the ambient temperature values indicated in the technical data.
• Make sure that heat produced by the device can be adequately vented into the
environment. Do not install the system in a cabinet without adequate air circulation.
• Never cover the air vents of the casing.
Important: Mechanical loads and electro-magnetic fields can impair PBX operation.