Auerswald COMpact 5000 Instructions Manual page 38

Pbx for isdn/analogue/internet telephony
Hide thumbs Also See for COMpact 5000:
Table of Contents

Advertisement

Available languages

Available languages

Important Information
Demarcations, Maximum Number
Internal U
ports
p0
External analogue ports
Internal analogue ports
External VoIP channels
Internal VoIP channels
Voice mail/fax channels
Additional devices (IP switch relays/boxes, announcement outputs, a/b and IP
door terminals)
a/b and IP door terminals
Announcement outputs (e. g. a/b Audioboxes)
Relays/actuators (as part of additional devices)
Feeder for all S
/U
0
p0
Internal Analogue Port for Analogue Terminals
Type of dialling
Open-circuit voltage
Loop current
Feeder
Range
Call voltage
Audible signals
Impedances
Internal S
Port for ISDN Terminals
0
Connection type
Supply voltage
Feeder
Range
Terminators
38
/a/b ports
Pulse or tone dialling
Max. 40 VDC
Approx. 23 mA
0.5 W
2 x 50 Ohm, approx. 800 m at 0.6 mm diameter
Approx. 45 V
425 Hz +/-5 %, interval +/-10 %
Symmetrical
S
basis access as Point-to-Multipoint connection, EURO-
0
ISDN (DSS1), short passive bus
40 V +5 % / -15 %
Max. 4 W
Max. 150 m with typical telephone or network cable
(twisted-pair) for bus setup; European standards
ENV 41001 [DINV 41001] and EN 28877 apply to IAE-
termination technology)
Max. 1000 m for PTP wiring
100 Ohm, switchable; factory settings on
COMpact 5000/5000R - Firmware V6.8 - Instructions V04 04/2017
, configurable: 25/50 Hz
eff
10
6
16
14
16
8
16
8
4
24
40 W

Advertisement

Chapters

Table of Contents
loading

This manual is also suitable for:

Compact 5000r

Table of Contents