• Avoid mechanical loads (e. g. vibrations).
• Avoid the proximity of devices that generate electro-magnetic fields (e. g., radio sets,
professional radio equipment, amateur radio equipment, mobile phones, DECT systems,
WLAN routers, etc.).
• Protect the PBX from dirt, excessive dust, condensation, caustic liquids, and steam.
Requirements:
• 4 screws
• Connections close to the installation site:
– Freely accessible Schuko socket
– Wall socket or NT provided by the network provider; if the wall socket/NT is relatively
far away from the PBX, permanent cabling must first be laid between the devices
– Grounding conductor (potential compensation bar of the house installation or protective
earth conductor)
1.
Push the casing into the rack.
2.
Fasten the casing to the right and to the left with the brackets and the four screws.

Connecting the Earthing

Warning: Touching voltage-carrying conductors or telephone connections can cause
life-threatening electric shocks.
• Only a fixed installation is allowed for the connection of the earthing terminal of the PBX
to the potential compensation bar of the house installation or the protective earth
conductor. Plug connections are not allowed.
Requirements:
• Screw driver (Phillips)
• Connecting cable with at least 2.5 mm
section
• Grommet (ring-shaped cable shoe: insulated or non-insulated)
with an inner ring diameter of 4 mm min. and 6 mm max.
• Proper earth connection close to the installation site
(equipotential bonding rail of the house installation or
protective earth conductor)
1.
Connect the connecting cable to the potential compensation
bar of the house installation or the protective earth conductor.
2.
Guide the connecting cable to the rear side of the casing.
3.
Join the grommet to the connecting cable and attach it to the earthing terminal
COMpact 5000/5000R - Firmware V6.8 - Instructions V04 04/2017