Option modules

Typically, option modules are fitted at the factory according to the drive variant or
order.
WARNING! Obey the instructions in chapter
you ignore them, injury or death, or damage to the equipment can occur.
The drive has two option module slots:
• Front option: Communication module slot under the front cover.
• Side option: Multifunction extension module slot on the side of the drive.
For more information, refer to the option module manual for installation and wiring
instructions. For information on the side-mounted options:
BTAC-02 pulse encoder interface module
BREL-01 relay output extension module
BAPO-01 power extension module
Before you start the work, stop the drive and do the steps in section
before electrical work

To install a front option

1. Remove the front cover.
2. If you have the BIO-01 option module,
you can add one additional fieldbus
module on top of it. Use the high front
cover.
3. Carefully align the option module with Slot
1 in the front of the drive.
4. Fully push the option module into
position.
5. Push the plastic locking tab until it locks.
6. Tighten the locking screw.
7. Connect the applicable control cables
according to
Connecting the control
cables
on page 68.
on page
on page 15.
Electrical installation 75
Safety instructions
on page
153
on page
171
177
5
on page 13. If
Precautions
4
6

Hide quick links: