Figuration; Diagnostics - ABB ACS380 Hardware Manual

Hide thumbs Also See for ACS380:
Table of Contents

Advertisement

Encoder configuration
This parameter group selects the settings for the encoder.
No.
Name/Value
92 Encoder 1 configuration
92.10
Pulses/rev
0...65535

Diagnostics

With parameter 90.45 Motor feedback fault, you can select how the drive reacts when
it detects that the encoder signal is lost.
• 90.45 = 0 (Fault) – The drive generates a fault (7301 Motor speed feedback), and
the motor coasts to a stop.
• 90.45 = 1 (Warning) – The drive generates a warning (A7B0 Motor speed
feedback) and continues operation using estimated feedbacks.
If the drive generates this fault or warning:
Code
Fault/Warning
(hex)
7301
Motor speed feedback
4
3FC
3FD
A7B0
Motor speed feedback
4
3FC
3FD
BTAC-02 pulse encoder interface module 167
Description
Defines the TTL or HTL pulse number per revolution.
Cause
No motor speed feedback is received.
Drift detected.
Check for slippage between encoder and motor.
Incorrect motor feedback configuration
Incorrect motor speed
No motor speed feedback is received
Encoder drift detected.
Check for slippage between encoder and motor.
Incorrect motor feedback configuration
Incorrect motor speed
Def/FbEq16/32
32
1=1

Hide quick links:

Advertisement

Table of Contents
loading