Wiring - Encoder Power Supply Interface - ABB ACS380 Hardware Manual

Hide thumbs Also See for ACS380:
Table of Contents

Advertisement

Wiring – Encoder power supply interface
Connect the encoder power supply via the BTAC module. The same power supply
feeds power to the signal interface of the BTAC module. For the voltage and current
rating, refer to
Encoder interface
If you use a 24 V encoder, you can use the 24 V DC power supply of the drive for the
encoder and BTAC module. Make sure that you do not exceed the load capacity.
Refer to
Auxiliary voltage connection
1
V
0V
cc
1. Encoder
2. BTAC module
3. Encoder power supply
Use the following table to determine if you can use the drive's supply. Add the missing
figures and sum all: the sum value must not exceed the total load capacity of the
drives' supply.
Number of digital inputs used
BTAC-02
Encoder current requirement =
Total requirements for any other user connection(s) to drive's 24 V DC =
Total (must be less than the maximum load capacity of the drive's 24 V DC
supply) =
on page 168.
Loads with the drive's 24 V DC supply
BTAC-02 pulse encoder interface module 157
on page 74.
2
V
in
V
out
GND
3
V
cc
0V
× 15 mA each
50 mA
mA