Network Configuration Settings

Set the information of slave stations connected to the master station.
Setting method
The procedure for the network configuration settings is shown below.
1.
Select the module in "Module List" and drag it to "List of stations" or "Network map".
List of stations
Network map
2.
Set the required items.
3.
Select [Close with Reflecting the Setting] to finish the network configuration settings.
Set the station type of the own station to "Master Station (Duplex Function)" to be used in a redundant system.
For standby master station, select "General Local Station" from the "Module List" and set "Station Type" to
"Local Station (Standby Master Station)". The system B operates with the station number of the standby
master.
Setting items
Item
Mode Setting
TX Speed
Link Scan Time (Approx.)
Station No.
2 PARAMETER SETTINGS
60
2.3 Basic Settings
Drag and drop the text.
Description
Set the mode of the master station.
Set the transmission speed of the master station.
The estimate value of link scan time is displayed.
For the estimate value of link scan time, refer to following.
Page 169 Link scan time
■For the master station
• 0/0 is displayed.
■For a slave station
• The order of the slave station is displayed before the slash.
• The start station number of the slave station is displayed after the slash.
Setting range
• Ver.1 Mode
• Ver.2 Mode
• Ver.1 Mode (Remote Device Net)
• Ver.2 Mode (Remote Device Net)
• Remote I/O Mode
(Default: Mode set in "Mode" under
"Required Settings")
• 156kbps
• 625kbps
• 2.5Mbps
• 5Mbps
• 10Mbps
(Default: Value set in "Transmission Speed"
under "Required Settings")