Mitsubishi Electric MELSEC iQ-R Series User Manual page 165

Melsec iq-r cc-link system master/local module
Hide thumbs Also See for MELSEC iQ-R Series:
Table of Contents

Advertisement

No.
Name
Description
SW007C
Temporary error
Stores whether a station is in the temporary error invalid status.
to
invalid status
0: Normal
SW007F
1: Temporary error invalid status
SW007C
SW007D
SW007E
SW007F
The bits turn on by the number of occupied stations.
Error invalid stations, reserved stations, station with the end station number, and
stations later than that are excepted.
SW0080
Data link status
Stores the data link status of each station.
to
of other stations
0: Normal
SW0083
1: Data link error
SW0080
SW0081
SW0082
SW0083
The bits turn on by the number of occupied stations.
It takes maximum of six seconds for this register to turn on after a slave station
connected to the master station or local station becomes faulty. The time until this
signal turns on differs depending on the system configuration and error status.
Temporary error invalid stations, error invalid stations, reserved stations, station
with the end station number, and stations later than that are excepted.
SW0084
Watchdog timer
Stores whether a watchdog timer error has occurred.
to
error occurrence
0: No watchdog timer error
SW0087
status of other
1: Watchdog timer error
stations
SW0084
SW0085
SW0086
SW0087
Only the bit corresponding to the start station number turns on.
Reserved stations, station with the end station number, and stations later than
that are excepted.
SW0088
Fuse blown
Stores whether a fuse blown error has occurred.
to
status of other
0: Normal
SW008B
stations
1: Fuse blown
SW0088
SW0089
SW008A
SW008B
The bits turn on by the number of occupied stations.
Reserved stations, station with the end station number, and stations later than
that are excepted.
b15
b14
b13
b12
to
16
15
14
13
to
32
31
30
29
to
47
46
45
to
48
64
63
62
61
to
1 to 64 in the table indicate station numbers.
b15
b14
b13
b12
to
16
15
14
13
to
32
31
30
29
to
to
48
47
46
45
64
63
62
61
to
1 to 64 in the table indicate station numbers.
b15
b14
b13
b12
to
16
15
14
13
to
32
31
30
29
to
to
48
47
46
45
64
63
62
61
to
1 to 64 in the table indicate station numbers.
b14
b13
b12
to
b15
16
15
14
13
to
32
31
30
29
to
48
47
46
45
to
64
63
62
61
to
1 to 64 in the table indicate station numbers.
Availability (: Available, : Not
available)
Online
Master
station
b3
b2
b1
b0
4
3
2
1
20
19
18
17
36
35
34
33
52
51
50
49
b3
b2
b1
b0
4
3
2
1
20
19
18
17
36
35
34
33
52
51
50
49
b3
b2
b1
b0
4
3
2
1
20
19
18
17
36
35
34
33
52
51
50
49
b3
b2
b1
b0
4
3
2
1
20
19
18
17
36
35
34
33
52
51
50
49
Appendix 5 List of Link Special Register (SW) Areas
Offline
Local
station
APPX
163
A

Advertisement

Table of Contents
loading

Table of Contents