Mitsubishi Electric MELSEC iQ-R Series User Manual page 47

Melsec iq-r cc-link system master/local module
Hide thumbs Also See for MELSEC iQ-R Series:
Table of Contents

Advertisement

(Input of the standby master station)
Master station
Remote
Remote
input (RX)
output (RY)
RX00 to RX0F
RY00 to RY0F
RX10 to RX1F
RY10 to RY1F
RX20 to RX2F
RY20 to RY2F
RX30 to RX3F
RY30 to RY3F
RX40 to RX4F
RY40 to RY4F
RX50 to RX5F
RY50 to RY5F
Inputs (RX and RWr) of the master station are stored in the outputs (RY and RWw) of the standby master station. By
transferring the outputs (RY and RWw) of the standby master station to the inputs (RX and RWr), inputs from the slave
stations are continued. (Shaded areas in the figure above) ( Page 86 Communication Example Using the Standby Master
Function)
■Operation between the master station returning and the standby master station controlling
data link
(Output from the standby master station)
Master station (standby status)
(station No.: 0→1, number of
occupied stations: 1)
Remote
Remote
input (RX)
output (RY)
RX00 to RX0F
RY00 to RY0F
RX10 to RX1F
RY10 to RY1F
RX20 to RX2F
RY20 to RY2F
RX30 to RX3F
RY30 to RY3F
RX40 to RX4F
RY40 to RY4F
RX50 to RX5F
RY50 to RY5F
Outputs (RY and RWw) from the standby master station are stored in inputs (RX and RWr) of the master station. (Shaded
areas in the figure above)
(Input of the standby master station)
Master station (standby status)
(station No.: 0→1, number of
occupied stations: 1)
Remote
Remote
output (RY)
input (RX)
RX00 to RX0F
RY00 to RY0F
RX10 to RX1F
RY10 to RY1F
RX20 to RX2F
RY20 to RY2F
RX30 to RX3F
RY30 to RY3F
RX40 to RX4F
RY40 to RY4F
RY50 to RY5F
RX50 to RX5F
Inputs (RX and RWr) from slave stations to the standby master station are stored in outputs (RY and RWw) of the master
station. (Shaded areas in the figure above)
Standby master station
(controlling)
(station No.: 1→0)
Remote
Remote
input (RX)
output (RY)
RX00 to RX0F
RY00 to RY0F
RX10 to RX1F
RY10 to RY1F
RX20 to RX2F
RY20 to RY2F
RX30 to RX3F
RY30 to RY3F
RX40 to RX4F
RY40 to RY4F
RX50 to RX5F
RY50 to RY5F
Standby master station
(controlling)
(station No.: 0)
Remote
Remote
input (RX)
output (RY)
RX00 to RX0F
RY00 to RY0F
RX10 to RX1F
RY10 to RY1F
RX20 to RX2F
RY20 to RY2F
RX30 to RX3F
RY30 to RY3F
RX40 to RX4F
RY40 to RY4F
RX50 to RX5F
RY50 to RY5F
Standby master station
(controlling)
(station No.: 0)
Remote
Remote
output (RY)
input (RX)
RX00 to RX0F
RY00 to RY0F
RX10 to RX1F
RY10 to RY1F
RX20 to RX2F
RY20 to RY2F
RX30 to RX3F
RY30 to RY3F
RX40 to RX4F
RY40 to RY4F
RX50 to RX5F
RY50 to RY5F
Remote I/O station
(station No.: 2, number of
occupied stations: 1)
X00 to X0F
Y00 to Y0F
X10 to X1F
Y10 to Y1F
Remote I/O station
(station No.: 2, number of
occupied stations: 1)
X00 to X0F
Y00 to Y0F
X10 to X1F
Y10 to Y1F
Remote I/O station
(station No.: 2, number of
occupied stations: 1)
X00 to X0F
Y00 to Y0F
X10 to X1F
Y10 to Y1F
1.3 Standby Master Function
Remote I/O station
(station No.: 3, number of
occupied stations: 1)
X00 to X0F
Y00 to Y0F
X10 to X1F
Y10 to Y1F
Remote I/O station
(station No.: 3, number of
occupied stations: 1)
X00 to X0F
Y00 to Y0F
X10 to X1F
Y10 to Y1F
Remote I/O station
(station No.: 3, number of
occupied stations: 1)
X00 to X0F
Y00 to Y0F
X10 to X1F
Y10 to Y1F
1 FUNCTIONS
1
45

Advertisement

Table of Contents