No.
Name
SW0144
CC-Link Ver.
to
installation/
SW0147
parameter
matching status
SW0148
Parameter
mode
SW0149
Parameter
mode of own
station
SW0152
Maximum
communication
station number
SW0153
Number of
connected
modules
involved in
communication
SW0160
Remote register
to
use prohibited
SW0163
status
APPX
166
Appendix 5 List of Link Special Register (SW) Areas
Description
Stores whether a CC-Link version matches between the parameter settings and
the modules on slave stations.
0: Normal
1: Mismatch error
b15
b14
b13
SW0144
16
15
14
SW0145
32
31
30
SW0146
48
47
46
SW0147
64
63
62
■Example of a mismatch error
Installation
Ver.2-compatible remote device station
Ver.1-compatible remote device station
The bits corresponding to the start station number and the number of occupied
stations turn on.
Reserved stations, station with the end station number, and stations later than
that are excepted.
Stores the mode set to a system.
0: Remote net Ver.1 mode, Remote device net Ver.1 mode, Remote I/O net
mode
2: Remote net Ver.2 mode, Remote device net Ver.2 mode
Stores the mode set to the own station.
0: Remote net Ver.1 mode, Remote device net Ver.1 mode, Remote I/O net
mode
2:Remote net Ver.2 mode, Remote device net Ver.2 mode
Stores the maximum station number during data link in real time (1 to 64: station
number in the station number setting).
Reserved stations, error invalid stations, and temporary error invalid stations are
excepted.
Stores the number of modules performing data link in real time.
Reserved stations, error invalid stations, and temporary error invalid stations are
excepted.
Stores whether the use of the remote register is prohibited.
0: Available
1: Use prohibited
b15
b14
b13
SW0160
16
15
14
SW0161
32
31
30
SW0162
48
47
46
SW0163
64
63
62
Only the bit corresponding to the start station number turns on.
Error invalid stations, reserved stations, station with the maximum station
number, and stations later than that are excepted.
b12
to
b3
b2
b1
to
13
4
3
2
29
to
20
19
18
45
to
36
35
34
61
to
52
51
50
1 to 64 in the table indicate station numbers.
Parameter
Ver.1-compatible remote device station
Ver.2-compatible remote device station
b12
to
b3
b2
b1
13
to
4
3
29
to
20
19
18
45
to
36
35
34
61
to
52
51
50
1 to 64 in the table indicate station numbers.