Mitsubishi Electric MELSEC iQ-R Series User Manual page 42

Melsec iq-r cc-link system master/local module
Hide thumbs Also See for MELSEC iQ-R Series:
Table of Contents

Advertisement

Setting method
Configure the remote I/O station points setting in "Network Configuration Settings" under "Basic Settings". ( Page 60
Network Configuration Settings)
When setting eight-point remote I/O stations, set an even number of stations consecutively. When setting an
odd number of eight-point remote I/O stations, select "8 Points + Empty 8 Points" from "Remote Station
Points" for the last of consecutive remote I/O stations.
The following figure shows an example of when three output modules with eight points are connected.
Master station
Remote output (RY)
Station
No.2
Empty
When the number of remote I/O stations is odd, eight points cannot be set in the remote station points.
Master station
Remote output (RY)
Station
No.2
This parameter cannot be set using dedicated instructions. Therefore, read or write data from/to the device in
a CPU module according to the number of I/O points of each station using a program. Consequently, the
areas in refresh devices can be saved.
• Reading/writing data using a module access device (Un\G)
• Reading/writing data using the FROM/TO instructions
Precautions
Set the number of points greater than the I/O points of a remote I/O station connected. If the smaller number of points is set in
a station, data cannot be normally input to or output from stations after that.
1 FUNCTIONS
40
1.1 Cyclic Transmission
Remote I/O station
(station No.: 1,
number of occupied
stations: 1)
Station
Y07 to Y00
No.1
Station
No.3
Station
No.4
·
8-point output
module
8 points + Empty 8 points
Remote I/O station
(station No.: 1,
number of occupied
stations: 1)
Station
Y07 to Y00
No.1
Station
No.3
Station No.4
·
8-point output
module
Cannot be set
Remote I/O station
Remote I/O station
(station No.: 2,
(station No.: 3,
number of occupied
number of occupied
stations: 1)
stations: 1)
Y07 to Y00
Y07 to Y00
8-point output
8-point output
module
module
Remote I/O station
Remote I/O station
(station No.: 2,
(station No.: 3,
number of occupied
number of occupied
stations: 1)
stations: 1)
Y07 to Y00
Y07 to Y00
8-point output
8-point output
module
module
Remote I/O station
(station No.: 4,
number of occupied
stations: 1)
Y0F to Y00
Y1F to Y10
32-point output
module
Remote I/O station
(station No.: 4,
number of occupied
stations: 1)
Y0F to Y00
Y1F to Y10
32-point output
module

Advertisement

Table of Contents
loading

Table of Contents