Error
Error details and causes
code
B605H
The transient storage buffer data was failed to be obtained.
B606H
System error
B607H
The CPU module on the target station is in error.
B608H
Transient transmission was performed to the AJ61BT11 or
A1SJ61BT11 in the I/O mode.
B60CH
System error
B700H
System error
B701H to
Transient transmission failed.
B704H
B705H
System error
B706H
System error
B771H
Too many transient requests were sent to the
corresponding station.
B772H
System error
B773H
System error
B774H
The target station was not an intelligent device station.
B775H to
Unsupported transient data was received.
B777H
B778H
A response is not received from the request destination.
B779H
System error
B780H
Transient transmission was performed although the target
station was set to I/O mode.
B781H
System error
B782H
When connection to another station is set, the sending
destination station and the sending source station are the
same.
B783H
When data larger than 1K was being sent in transient
transmission, an error has occurred in the transient storage
buffer.
B801H
A non-existing access code or attribute is set.
B802H
A non-existing access code was used.
B803H
The number of data points is out of the range.
B804H
• The attribute definition is invalid.
• A transient transmission was performed although the
target station does not support transient transmission.
B805H
The number of data points is out of the range.
B807H
• The start device number is out of the range.
• The address was not a multiple of 16 when the bit device
was accessed.
B80AH
System error
B80DH
The set combination (address and number of points)
exceeded the processable range.
B80FH to
System error
B812H
B814H
The file register capacity is not set.
B815H
Transient transmission was performed although the target
station was set to I/O mode.
B817H
System error
B821H
System error
B822H
System error
B823H
The mode setting of the remote control is not correct.
B824H
System error
B826H
System error
4 TROUBLESHOOTING
128
4.6 List of Error Codes
Action
Wait for a while and send the request again.
Please consult your local Mitsubishi representative.
Check the CPU module of the target station.
Set the target station to intelligent mode.
Please consult your local Mitsubishi representative.
Please consult your local Mitsubishi representative.
• Reduce the load placed on the transient transmission
and perform the transmission again.
• If the error occurs again even after taking the above,
please consult your local Mitsubishi representative.
Please consult your local Mitsubishi representative.
Please consult your local Mitsubishi representative.
Wait for a while and send the request again.
Please consult your local Mitsubishi representative.
Please consult your local Mitsubishi representative.
Check if the target station is an intelligent device station.
Check the application on the source that issued the
request.
Check the modules and cables at the request destination.
Please consult your local Mitsubishi representative.
Set the target station to intelligent mode.
Please consult your local Mitsubishi representative.
Check the station number of the destination or change the
setting to connection to the own station.
Wait for a while and send the request again.
Set the correct access code or attribute.
Use the correct access code.
Set the number of data points within 1 to 960 bytes.
• Correct the attributes definition.
• Correct the target station number setting.
• Correct the function version of the target local station
and software version.
Set a value within 1 to 100 for writing and within 1 to 160
for reading.
• Set the start device number within the range.
• Set the address in multiples of 16 when the bit device is
accessed.
Please consult your local Mitsubishi representative.
Set the number of points to be processed within the device
range.
Please consult your local Mitsubishi representative.
Set the file register capacity.
Set the target station to intelligent mode.
Please consult your local Mitsubishi representative.
Please consult your local Mitsubishi representative.
Please consult your local Mitsubishi representative.
Correct the mode specification.
Please consult your local Mitsubishi representative.
Please consult your local Mitsubishi representative.