Mitsubishi Electric MELSEC iQ-R Series User Manual page 166

Melsec iq-r cc-link system master/local module
Hide thumbs Also See for MELSEC iQ-R Series:
Table of Contents

Advertisement

No.
Name
SW008C
Switch change
to
status of other
SW008F
stations
SW0090
Line status
SW0094
Transient
to
transmission
SW0097
status
SW0098
Station number
to
overlap status
SW009B
APPX
164
Appendix 5 List of Link Special Register (SW) Areas
Description
Stores whether the setting of switches of other stations during data link has been
changed.
0: No change
1: Changed
b15
b14
b13
SW008C
16
15
14
SW008D
32
31
30
SW008E
48
47
46
SW008F
64
63
62
Only the bit corresponding to the start station number turns on.
Reserved stations, station with the end station number, and stations later than
that are excepted.
Stores the line status.
0: Normal
1: Data link disabled (disconnected)
Stores whether a transient transmission error has occurred.
0: No transient transmission error
1: Transient transmission error
b15
b14
b13
SW0094
16
15
14
SW0095
32
31
30
SW0096
48
47
46
SW0097
64
63
62
Only the bit corresponding to the start station number turns on.
Reserved stations, station with the end station number, and stations later than
that are excepted.
Stores whether station numbers are unique when the start station numbers of
modules are different.
0: Normal
1: Station number in use (start station number only)
b14
b13
b15
SW0098
14
16
15
SW0099
32
31
30
SW009A
48
47
46
SW009B
64
63
62
Reserved stations, station with the end station number, and stations later than
that are excepted.
Only the bit corresponding to the start station number turns on. This item is
checked, and the result is stored only upon data link start and the change of a
parameter.
For a slave station with the transmission speed auto-tracking setting, whether the
station number is already used for other stations may not be detected.
When the station number of a station is the same as that of the standby master
station, the status cannot be detected.
b12
to
b3
b2
b1
to
13
4
3
2
29
to
20
19
18
45
to
36
35
34
61
to
52
51
50
1 to 64 in the table indicate station numbers.
b12
to
b3
b2
b1
13
to
4
3
2
29
to
20
19
18
45
to
36
35
34
61
to
52
51
50
1 to 64 in the table indicate station numbers.
b12
to
b3
b2
b1
13
to
4
3
29
to
20
19
18
45
to
36
35
34
61
to
52
51
50
1 to 64 in the table indicate station numbers.
Availability (: Available, : Not
available)
Online
Master
Local
station
station
b0
1
17
33
49
b0
1
17
33
49
b0
2
1
17
33
49
Offline

Advertisement