Mitsubishi Electric MELSEC iQ-R Series User Manual page 140

Melsec iq-r cc-link system master/local module
Hide thumbs Also See for MELSEC iQ-R Series:
Table of Contents

Advertisement

Address
Hexadecimal
Decimal
3000H to 3FFFH
12288 to 16383
4000H to 41FFH
16384 to 16895
4200H to 43FFH
16896 to 17407
4400H to 4BFFH
17408 to 19455
4C00H to 53FFH
19456 to 21503
5400H to 5C7FH
21504 to 23679
5C80H to 5CBFH
23680 to 23743
5CC0H to 7FFFH
23744 to 32767
*1 Not available when a standby master station is controlling the system.
*2 This buffer memory area is used when the remote net Ver.1 mode, remote device net Ver.1 mode, or remote I/O net mode is selected.
*3 This buffer memory area is used when the remote net Ver.2 mode or remote device net Ver.2 mode is selected.
Do not write data to "System area".
Doing so may cause malfunction of the programmable controller system.
APPX
138
Appendix 3 Buffer Memory
Name
Description
System area
Ver.2-
■Master station
compatible
Stores the data input from slave
remote input
stations.
*3
(RX)
■Local station
Stores the data input from the master
station.
■Master station
Ver.2-
compatible
Stores the data output to slave
remote output
stations.
*3
(RY)
■Local station
Stores the data output to the master
station. Data input from other slave
stations are also stored.
■Master station
Ver.2-
compatible
Stores the send data to slave
remote
stations.
register
*3
(RWw)
■Local station
Stores the send data to the master
station and other salve stations. Data
received from other slave stations are
also stored.
■Master station
Ver.2-
compatible
Stores the data received from slave
remote
stations.
register
*3
(RWr)
■Local station
Stores the data received from the
master station.
System area
Remote
Stores the execution progress of the
device station
remote device station initial setting
initialization
procedure registration function.
procedure
registration
execution
individual
information
System area
Read/
Availability
write
Master
Local
station
station
Read
Read, write
Read, write
Read
Read
Reference
Page 149 Ver.2-
compatible remote
input (RX) and Ver.2-
compatible remote
output (RY)
Page 149 Ver.2-
compatible remote
input (RX) and Ver.2-
compatible remote
output (RY)
Page 150 Ver.2-
compatible remote
register (RWw) and
Ver.2-compatible
remote register
(RWr)
Page 149 Ver.2-
compatible remote
input (RX) and Ver.2-
compatible remote
output (RY)
Page 150 Ver.2-
compatible remote
register (RWw) and
Ver.2-compatible
remote register
(RWr)
Page 150 Ver.2-
compatible remote
register (RWw) and
Ver.2-compatible
remote register
(RWr)
Page 150 Ver.2-
compatible remote
register (RWw) and
Ver.2-compatible
remote register
(RWr)
Page 150 Ver.2-
compatible remote
register (RWw) and
Ver.2-compatible
remote register
(RWr)
Page 151 Remote
device station
initialization
procedure
registration
execution individual
info.

Advertisement

Table of Contents
loading

Table of Contents