Quick Setting Menu (-Quick-); Quick Setting Parameter Access Procedure; Quick Setting Parameter List - YASKAWA P7 User Manual

Table of Contents

Advertisement

Quick Setting Menu (-QUICK-)

This menu is used to set/read the most commonly used parameters in the Drive. Follow the key operations below (Fig. 3.6) to
access the Quick Setting Menu:
Use
and
keys to scroll through the "Quick Setting" parameter list.
Parameter
Number
A1-00
b1-01
b1-02
b1-03
b1-04
b4-01
b5-01
b5-02
b5-03
b5-04
b5-06
b5-07
b5-08
b5-09
b5-10
b5-11
b5-12
PI Feedback Reference Missing Detection Selection
b5-13
b5-14
b5-15
b5-16
b5-17
b5-18
b5-19
b5-20
b5-21
b5-22
b5-23
b5-24
b5-25
b5-26
b5-27
b5-28
PI Feedback Square Root Ac Function Selection
-QUICK-
** Main Menu **
- - - - - - - - - - - - - -
Quick Setting
x2
Fig 3.6 Quick Setting Parameter Access Procedure
Table 3.11 Quick Setting Parameter List
Parameter Name
Language Selection
Frequency Reference Selection
Run command Selection
Stopping Method Selection
Reverse Operation Selection
Delay-On Timer
PI Mode Selection
Proportional Gain Setting
Integral Time Setting
Integral Limit Setting
PI Output Limit
PI Offset Adjustment
PI Primary Delay Time
PI Output Level Selection
PI Output Gain Setting
PI Output Reverse Selection
PI Feedback Loss Detection Level
PI Feedback Loss Detection Time
PI Sleep Function Start Level
PI Sleep Delay Time
PI Accel/Decel Time
PI Setpoint Selection
PI Setpoint Value
PI Setpoint Display Setting
PI Sleep Input Source
PI Snooze Level
PI Snooze Delay Time
PI Snooze Deactivation Level
PI Setpoint Boost Setting
PI Maximum Boost Time
PI Snooze Feedback Level
Parameter
Number
b5-29
b5-30
b8-01
C1-01
C1-02
d2-01
d2-02
E1-01
E2-01
F6-01
H3-02
H3-03
H3-10
H3-11
L2-01
L2-02
L4-05
L4-06
L5-01
L5-03
L6-01
L6-02
L6-03
L8-11
o1-01
o1-05
o1-07
o1-08
o2-03
o2-05
o2-08
o3-02
Digital Operator 3 - 11
-QUICK-
Reference Source
- - - - - - - - - - - - - - - - - - - -
B1-01=
1
*1*
Terminals
"1"
Parameter Name
PI Square Root Gain
Output Square Root Monitor Selection
Energy Savings Control Selection
Acceleration Time 1
Deceleration Time 1
Frequency Reference Upper Limit
Frequency Reference Lower Limit
Input Voltage Setting
Motor Rated Current
Operation Selection After Communication Error
Terminal A1 Gain Setting
Terminal A1 Bias Setting
Terminal A2 Gain Setting
Terminal A2 Bias Setting
Momentary Power Loss Detection Selection
Momentary Power Loss Ride-thru Time
Frequency Reference Loss Detection Selection
Frequency Reference Level at Loss Frequency
Number of Auto Restarts Attempts
Maximum Restart Time After Fault
Torque Detection Selection 1
Torque Detection Level 1
Torque Detection Time 1
Heatsink Cooling Fan Operation Delay Time
User Monitor Selection
LCD Brightness Adjustment
Second Line User Monitor Selection
Third Line User Monitor Selection
User Parameter Default Value
Frequency Operation Time Selection
Cumulative Operation Time Selection
Read Allowed Selection

Hide quick links:

Advertisement

Table of Contents
loading