Parameter
Parameter Name
No.
Digital Operator Display
PI Output Gain Setting
b5-10
Output Gain
PI Output Reverse Selection
b5-11
Output Rev Sel
PI Feedback Reference
b5-12
Missing Detection Selection
Fb los Det Sel
PI Feedback Loss Detection
b5-13
Level
Fb los Det Lvl
PI Feedback Loss Detection
b5-14
Time
Fb los Det Time
Sleep Function Start
b5-15
Level
Sleep Level
Sleep Delay Time
b5-16
Sleep Time
PI Accel/Decel Time
b5-17
PI Acc/Dec Time
PI Setpoint Selection
b5-18
PI Setpoint Sel
b5-19
PI Setpoint Value
!
PI Setpoint
PI Setpoint Display Scaling
b5-20
Setpoint Scaling
PI Sleep Input Source
b5-21
PI Sleep Source
b5-22
PI Snooze Level
!
Snooze Level
PI Snooze Delay Time
b5-23
Snooze Delay Time
PI Snooze Deactivation Level
b5-24
Wake-Up Level
PI Setpoint Boost Setting
b5-25
Setpoint Boost
PI Maximum Boost Time
b5-26
Max Boost Time
PI Snooze Feedback Level
b5-27
Snooze Feedback
PI Feedback Square Root
b5-28
Function Selection
PI Feedback SqRt
PI Square Root Gain
b5-29
PI Fb SqRt Gain
Output Square Root
b5-30
Monitor Selection
PI Out Moni SqRt
!Denotes that parameter can be changed when the drive is running.
Table 1: Parameter List (Continued)
Description
Sets the output gain of the PI controller.
0: 0 limit (when PI output goes negative Drive stops)
1: Reverse (when PI goes negative Drive reverses)
0 limit automatic when reverse prohibit is selected using b1-04
0: Disabled
1: Alarm
2: Fault
Sets the PI feedback loss detection level as a percentage of
maximum frequency (E1-04).
Sets the PI feedback loss detection delay time in terms of seconds.
Sets the sleep function start frequency.
Sets the sleep function delay time in terms of seconds.
Applies an accel/decel time to the PI setpoint reference.
0: Disabled
1: Enabled
Depends on b5-20.
Set display/setting Unit of b5-19.
Input Source Selection for Sleep function Mode.
0: SFS Input (This is near the PI Output.)
1: PI Setpoint
2: Snooze
Sets the PI snooze function start level as a percentage of maximum
frequency (E1-04).
Sets the PI snooze function delay time in terms of seconds.
When the PI feedback drops below this level, normal PI operation
starts again. Set as a percentage of maximum frequency (E1-04).
Temporary increase of PI setpoint to create an overshoot of the
intended PI setpoint.
Sets a time limitation for reaching temporarily boosted PI setpoint
(intended PI setpoint + b5-25).
PI snooze mode will be activated when PI feedback is above this
level. Set as a percentage of maximum frequency (E1-04).
0: Disabled
1: Enabled
A multiplier applied to the square root of the feedback.
0: Disabled
1: Enabled
Parameters A - 6
Setting
Factory
Menu
Range
Setting
Location
0.0 to 25.0
1.0
Quick Setting
0 or 1
0
Quick Setting
0 to 2
0
Quick Setting
0 to 100
0%
Quick Setting
0.0 to 25.5
1.0sec
Quick Setting
0.0 to 200.0
0.0Hz
Quick Setting
0.0 to 25.5
0.0sec
Quick Setting
0.0 to 25.5
0.0sec
Quick Setting
0 or 1
0
Quick Setting
0.00 to
0.00%
Quick Setting
100.00
0 to 39999
1
Quick Setting
0 to 2
1
Quick Setting
0 to 100
0%
Quick Setting
0 to 3600
0sec
Quick Setting
0 to 100
0%
Quick Setting
0 to 100
0%
Quick Setting
0 to 3600
0sec
Quick Setting
0 to 100
60%
Quick Setting
0 or 1
0
Quick Setting
0.00 to 2.00
1.00
Quick Setting
0 or 1
0
Quick Setting