Parameter
Parameter Name
No.
Digital Operator Display
LCD Brightness Adjustment
o1-05
LCD Contrast
User Monitor Selection Mode
o1-06
Monitor Mode Sel
Second Line User Monitor
o1-07
Selection
2nd Monitor Sel
Third Line User Monitor
o1-08
Selection
3rd Monitor Sel
Local/Remote Key Function
o2-01
Selection
Local/Remote Key
OFF Key Function During Auto
o2-02
Run
Oper STOP Key
User Parameter Default Value
o2-03
User Defaults
Drive/kVA Selection
o2-04
Inverter Model #
Frequency Reference Setting
o2-05
Method Selection
Operator M.O.P.
Operation Selection when Digital
o2-06
Operator is Disconnected
Oper Detection
Cumulative Operation Time
o2-07
Setting
Elapsed Time Set
!Denotes that parameter can be changed when the drive is running.
Table 1:
Parameter List (Continued
Description
Set Value
Description
5
LCD display becomes dark.
3
Standard setting
1
LCD display becomes light.
Selects the "U1" monitors displayed on the 4th and 5th
lines of the digital operator display.
0: 3 Mon Sequential (Displays the next 2 sequential U1
monitors.)
1: 3 Mon Selectable (Displays U1 monitors set by o1-07
and o1-08.)
Sets the "U1" monitor always displayed on the 4th line
of the digital operator display. Effective only when o1-
06 = 1.
Sets the "U1" monitor always displayed on the 5th line
of the digital operator display. Effective only when
o1-06 = 1.

Key Selections

Determines if the Digital Operator Local/Remote key is
functional.
0: Disabled
1: Enabled
Determines if the off key on the digital operator will
stop the drive when drive is operating from external
terminals or serial communications.
0: Disabled
1: Enabled
Allows storing of current parameter values as a User
Initialization Selection at parameter A1-03.
0: No Change (No user parameter set active).
1: Set Defaults (Saves current parameter settings as user
initialization. A1-03 now allows selecting <1110> for
user initialization.
2: Clear All (Clears the currently saved user
initialization. A1-03 no longer allows selecting
<1110>.
Sets the kVA of the drive. Enter the number based on
drive Model #. Use the """" portion of the
CIMR-E7"""" Model Number.
Reference Appendix 2
Determines if the Data/Enter key must be used to input
a frequency reference from the digital operator.
0: Disabled - Data/Enter key must be pressed to enter a
frequency reference.
1: Enabled - Data/Enter key is not required. The
frequency reference is adjusted by the up and down
arrow keys on the digital operator without having to
press the data/enter key.
Determines if the drive will stop when the digital
operator is removed.
0: Disabled - The drive will not stop when the digital
operator is removed. (Must also set o2-15=0)
1: Enabled - The drive will fault (OPR) and coast to
stop when the operator is removed.
Sets the initial value of the elapsed operation timer.
Parameters A - 24
)
Setting
Factory
Range
Setting
0 to 5
3
0 or 1
0
1 to 53
2
1 to 53
3
0 or 1
1
0 or 1
1
0 to 2
0
kVA
0 to FF
Dependent
0 or 1
1
0 or 1
1
0 to 65535
0 hours
Menu
Location
Quick Setting
Programming
Quick Setting
Quick Setting
Programming
Programming
Quick Setting
Programming
Quick Setting
Programming
Programming