1.7.1) Current input (measured with both fuel pumps ON)
12 V
14 V
16 V
1.7.2) Fine filter
The fine filter must be installed such that it is easily accessible for mainte-
nance work and can be inspected as per the maintenance overview.
The fine filter must be installed between the pumps and the injection
valves.
An additional filter with mesh size 0.050-0.067 mm (0.002-0.003 in.) must
be installed in the supply line between the tank and the fuel pumps.
A combination of filter/water trap is recommended.
1.8)
General requirements placed on the fuel pumps
Min. delivery rate
Min. fuel pump pressure
Effectivity: 912 i Series
Edition 1/Rev. 0
BRP-Powertrain
INSTALLATION MANUAL
Voltage
9.1 A
10.1 A
11.2 A
Non-compliance can result in serious injuries or
WARNING
WARNUNG
death!
The pressure in the return line must not exceed the
value stipulated in section 1.4.
Requirement
Amperage
regarding delivery
56 l/h (14.79 USgal)
4.5 bar (65.26 psi) (at sea level)
73-00-00
Page 6
January 01/2012