6) Internal power consumers

General note
Current consumption
Components
NOTE:
Effectivity: 912 i Series
Edition 1/Rev. 0
BRP-Powertrain
INSTALLATION MANUAL
Non-compliance can result in serious injuries or
WARNING
WARNUNG
death!
The current consumption of the remaining consumers
is to be limited so as to ensure that power is supplied
to the internal consumers (e.g. fuel pumps, ECU, ser-
vomotors, etc.) at all times.
See the performance diagrams of the internal and ex-
ternal alternators as a function of engine speed.
Components
Fuel pump (main pump)
Fuel pump (additional pump)
ECU
Warning lamp A
Warning lamp B
FUSE BOX
Total
A complete analysis of the current consumption of all the
fitted consumers is to be carried out by the aircraft or air-
frame manufacturer.
Current consumption
min. 10 A
min. 10 A
~ 1.2 A
max. 200 mA
max. 200 mA
tbd
24-00-00