5.2)
Switch requirements
Requirements
See following table.
LANE SELECT SWITCH A
Connector type
Min. switching voltage
Min. switching current
How many poles?
Designation on wiring harness
LANE SELECT SWITCH B
Connector type
Min. switching voltage
Min. switching current
How many poles?
Designation on wiring harness
Backup Battery SWITCH A
Connector type
Min. switching voltage
Min. switching current
How many poles?
Designation on wiring harness
FUSE BOX
Connector type
Min. switching voltage
Min. switching current
How many poles?
Designation on wiring harness
Main Switch
Effectivity: 912 i Series
Edition 1/Rev. 0
BRP-Powertrain
INSTALLATION MANUAL
FUEL PUMP SWITCH 1
Requirement
Toggle
250 VAC/30 VDC
5 A
1-pole
LANE_SEL_SW_A_1
LANE_SEL_SW_A_2
Requirement
Toggle
250 VAC/30 VDC
5 A
1-pole
LANE_SEL_SW_B_1
LANE_SEL_SW_B_2
Requirement
Toggle (but with mechanical in-
terlock to prevent switch on du-
ring standard operation).
250 VAC/30 VDC
20 A
2-pole
Not connected to the wiring
harness.
Must be installed by the aircraft
manufacturer.
Requirement
Toggle
250 VAC/30 VDC
10 A
1-pole
SIG_FUEL_PUMP_1
GND_FUEL_PUMP_1
Tbd
Connector/slot
HIC A
1
7
Connector/slot
HIC B
1
9
Connector/slot
FUSE BOX
Battery (+)
Connector/slot
HIC A
3
9
24-00-00
Page 21
January 01/2012