Installation Position Of The Fuse Box Assy - Rotax 912 i Series Installation Manual

Hide thumbs Also See for 912 i Series:
Table of Contents

Advertisement

Step
5
6
Fitting the AMP connector
Graphic
Fig. 5
2.4)

Installation position of the FUSE BOX assy.

Permissible ambient temperature:
Temperature
- Max. +80 °C (176 °F)
2.5)
Ambient air, pressure, temperature sensor (AAPTS)
The AAPTS sensor is the all-in-one sensor for engine ambient tempera-
General
ture and engine ambient pressure. In cowled engine installations it has to
be mounted in the engine compartment in a ram air free area and close to
the air inlet. The sensor should measure the correct air inlet temperature
and the air pressure right before the air filter.
Effectivity: 912 i Series
Edition 1/Rev. 0
BRP-Powertrain
INSTALLATION MANUAL
Check for tight fit.
Install strain relief clamp (4).
4
1
5
6
Part
1
2
3
4
5
6
7
Procedure
2
7
Function
Line
Socket contact
Connector
Strain relief clamp
Connector receptacle
Squeeze plate
Cable holder
3
76-00-00
Page 7
January 01/2012

Advertisement