1.2)
Starter relay assy. technical data
See
General note
- 12 V/DC
Nominal voltage
- Min. 6 V
Control voltage
- Max. 18 V
- Max. 75 A 8 (permanent)
Switching current
- Max. 300 A/1 sec. (short duration)
Permissible ambient temperature:
Temperature
- Min. -40 °C (-40 °F)
- Max. +100 °C (212 °F)
See chap. 72-00-00 section: 2.1).
Weight
Main current connections (1):
Connections
M6 screw connection (tightening torque 4 Nm (36 in.lb.)) suitable for
cable terminals according to DIN 46225 (MIL-T-7928; PIDG or equiva-
lent).
Control wiring (2):
6.3x0.8 plug connector suitable for Faston connector (female) according
to DIN 46247 (MIL-T-7928; (PIDG) or equivalent).
Grounding
Effectivity: 912 i Series
Edition 1/Rev. 0
BRP-Powertrain
INSTALLATION MANUAL
Fig. 3.
Activation of starter relay limited to short duration. The
NOTICE
WARNUNG
duty cycle over an interval of 4 minutes is 25%.
The starter relay must be isolated from the aircraft
NOTICE
WARNUNG
ground. See chap. 24-00-00 section: FUSE BOX con-
nections.