Points of Inspection
* no periodic maintenance (require-
ment after the first 25 hours of
operation)
Inspection of the GENUINE ROTAX®
exhaust system included in the stand-
ard delivery.
N N O O T T E E
If there is no standard/genuine ex-
haust system in use, the specifica-
tions of the manufacturer must be
observed.
Drain oil from oil tank.
Check the oil tank and clean the oil
tank if contaminated.
Refill oil tank with approx. 3 litres of oil.
For oil quality, see Operators Manual
latest edition.
Cleaning oil sieve in the oil sump.
Install new oil filter
)3
In the case more than 30% of operation with leaded fuel e.g.: AVGAS 100 LL
Inspect the fuel system on the engine
side for leaks.
Inspect the fuel system for damages.
Check the ECU and its mountings.
Effectivity: 915 i A Series
Edition 0/Rev. 0
BRP-Rotax
MAINTENANCE MANUAL
Interval Operating hours
25*
50
100
200
X
7) Oil change
X
X
)3
X
X
)3
X
X
)3
X
X
)3
X
X
X
X
8) Fuel system
X
X
9) Engine management
Chapter
Reference
600
1000
X
X
X
X
X
X
12–20–00
Oil change,
Flushing the
oil circuit
X
X
X
12–20–00
Oil change,
Cleaning the
oil tank
X
X
X
12–20–00
Flushing the
oil circuit,
Purging the
oil system
X
X
X
X
X
X
12–20–00
Oil filter
change
12–20–00
Fuel system
X
12–20–00
Checking
Signa-
ture
ECU
05–20–00
Page 11