Rotax 915 i A SERIES Maintenance Manual page 134

Hide thumbs Also See for 915 i A SERIES:
Table of Contents

Advertisement

General note
N N O O T T E E
It is advisable to check the oil level prior to an oil change as it informs about oil
consumption.
See
Observe
Observe the following to prevent possible unintentional voiding of the oil system
• Draining the suction lines, oil cooler and return line is not necessary and must be
• Replacement of the oil filter and the oil change should be effected quickly and without
12–20–00
Page 26
December 01 2017
MAINTENANCE MANUAL
Risk of burns and scalds. Hot engine parts.
Always allow engine to cool down to ambient temperature before starting work.
Ignition "OFF" and system grounded! Disconnect negative terminal of battery.
Chapter 12-10-00 section Oil level
avoided, as it results in air entering the oil system.
See
Chapter 12-20-00 section Purging the oil
interruption to prevent a draining of the oil system and the hydraulic tappets.
BRP-Rotax
m WARNING
m WARNING
Risk of electric shock!
check/Replenish.
ATTENTION
and damage to the valve drive:
system.
Effectivity: 915 i A Series
Edition 0/Rev. 0

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents