Safety notice
When working on the ECU, the general safety instruction must be observed. See chap-
Figure 7.4: Engine management ECU
CHECKING ECU
Instruction
For checking proceed as follows:
Step
READ OUT THE ECU DATA MEMORY
Instruction
For read out the ECU data memory proceed as follows:
Effectivity: 915 i A Series
Edition 0/Rev. 0
BRP-Rotax
MAINTENANCE MANUAL
ENGINE MANAGEMENT ECU
Non-compliance can result in serious injuries or death!
1
ECU
3
Socket for APM-connector
Procedure
1
Inspect the ECU (1) and ECU mounts (2) for secure attachment and
damage.
2
Inspect the ECU wiring for wear, chafing and other damage, and make sure
that the connectors are securely attached.
m WARNING
ter „INTRO".
Grounding clip
2
12–20–00
Page 11