Syntax
display environment [ slot slot-number ]
Views
Any view
Predefined user roles
network-admin
network-operator
Parameters
slot slot-number: Specifies an IRF member device by its member ID or a PEX by its virtual slot
number. If you do not specify this option on an IRF fabric, the command displays the temperature
statistics for all member devices. If you do not specify this option on an IRF 3 system, the command
displays the temperature statistics for all parent devices and PEXs.
Examples
# Display the temperature statistics for all temperature sensors on the device.
<Sysname>display environment
System temperature information (degree centigrade):
----------------------------------------------------------------------
Slot
Sensor
1
hotspot 1 40
1
hotspot 2 39
Table 38 Command output
Field
System temperature
information (degree
centigrade)
sensor
Slot x
Temperature
Lower
Warning
Alarm
Shutdown

display fan

Use display fan to display the operating states of fans.
Syntax
display fan [ slot slot-number [ fan-id ] ]
Views
Any view
Temperature
Lower
0
0
Description
Temperature information (°C).
Temperature sensor, hotspot for a hotspot sensor.
ID of the IRF member device or PEX.
Current temperature.
Low-temperature threshold.
High-temperature warning threshold.
High-temperature alarming threshold.
High-temperature shutdown threshold.
Warning
Alarm
Shutdown
50
55
NA
58
63
NA
238