Parameters
screen-length: Specifies the maximum number of lines to be displayed on a screen, in the range of 0
to 512. Setting this argument to 0 disables pausing between screens of output.
Usage guidelines
This command sets the maximum number of lines that can be displayed on one screen when the
screen pause feature is enabled. If the screen pause feature is disabled, the system displays
command output without a pause.
The actual number of lines that can be displayed on a screen is restricted by the display specification
of the configuration terminal. For example, if you set the maximum number of lines for a screen to 40,
the device sends 40 lines to the screen at a time. If the display specification is 24 lines, only the last
24 lines are displayed on the screen. To view the previous 16 lines, you must press PgUp.
The screen pause feature is enabled by default. To disable this feature, execute the screen-length 0
command or the screen-length disable command. The screen-length disable command is
available in user view.
This command is available in both user line view and user line class view. A non-default setting in
either view takes precedence over a default setting in the other view. A non-default setting in user
line view takes precedence over a non-default setting in user line class view.
Examples
# Set the maximum number of lines to be displayed on a screen to 30 for user line AUX 0.
<Sysname> system-view
[Sysname] line aux 0
[Sysname-line-aux0] screen-length 30
Related commands
screen-length disable

send

Use send to send messages to user lines.
Syntax
send { all | number1 | { aux | vty } number2 }
Views
User view
Predefined user roles
network-admin
Parameters
all: Specifies all user lines.
number1: Specifies the absolute number of a user line, in the range of 0 to 192.
aux: Specifies the AUX line.
vty: Specifies the VTY line.
number2: Specifies the relative number of a user line. The value range is 0 to 128 for the AUX line
and 0 to 63 for the VTY line.
Usage guidelines
To end a message, press Enter. To cancel a message and return to user view, press Ctrl+C.