Examples
# On a multichassis IRF fabric, perform a master/subordinate switchover during an ISSU to a
compatible version.
<Sysname> issu run switchover
Upgrade summary according to following table:
flash:/feature.bin
Running Version
Alpha 7122
Slot
1
Upgrading software images to compatible versions. Continue? [Y/N]:
# On a multichassis IRF fabric, perform a master/subordinate switchover and upgrade members that
have not been upgraded (member 1 and member 2) during an ISSU to an incompatible version.
<Sysname> issu run switchover
Copying file flash:/feature.bin to slot2#flash:/feature.bin...Done.
Upgrade summary according to following table:
flash:/feature.bin
Running Version
Alpha 7122
Slot
1
2
Upgrading software images to incompatible versions. Continue? [Y/N]:
Table 28 Command output
Field
Switchover Way
For descriptions of other fields, see
Related commands
issu load
reset install log-history oldest
Use reset install log-history oldest to clear ISSU log entries.
Syntax
reset install log-history oldest log-number
Views
User view
New Version
Alpha 7123
Switchover Way
Active standby process switchover
New Version
Alpha 7123
Upgrade Way
Reboot
Reboot
Description
Switchover method:
•
Active standby process switchover—Switch from the active process to the
standby process.
•
Master subordinate switchover—Switch from the master to a subordinate
member.
Table
25.