H3C S5830V2 Command Reference Manual page 205

Switch series fundamentals
Hide thumbs Also See for S5830V2:
Table of Contents

Advertisement

For an IRF fabric with a single member, this command ends the ISSU process. When this command
is completed, the ISSU status changes to Init, and the ISSU process cannot be rolled back.
At reboot, a subordinate device automatically synchronizes the master device's configuration and
status data. You must wait for the synchronization to complete before using the issu commit
command on the subordinate device. To check the synchronization progress, use the display device
command. The synchronization is completed when all member device are in normal state.
Examples
# After member 2 is upgraded and becomes the new master, upgrade the original master (member 3)
and the other subordinate members that have not been upgraded (member 4 and member 1).
<Sysname> issu commit slot 3
Upgrade summary according to following table:
flash:/feature.bin
Running Version
Alpha 7122
Slot
3
Upgrading software images to compatible versions. Continue? [Y/N]: y
<Sysname> issu commit slot 4
Copying file flash:/feature.bin to slot4#flash:/feature.bin...Done.
Upgrade summary according to following table:
flash:/feature.bin
Running Version
Alpha 7122
Slot
4
Upgrading software images to compatible versions. Continue? [Y/N]:y
<Sysname> issu commit slot 1
Copying file flash:/feature.bin to slot1#flash:/feature.bin...Done.
Upgrade summary according to following table:
flash:/feature.bin
Running Version
Alpha 7122
Slot
1
Upgrading software images to compatible versions. Continue? [Y/N]:y
For field descriptions, see
Related commands
issu accept
issu load
issu run switchover
New Version
Alpha 7123
Upgrade Way
Service Upgrade
New Version
Alpha 7123
Upgrade Way
Service Upgrade
New Version
Alpha 7123
Upgrade Way
Service Upgrade
Table
25.
193