2-2 Introducing the WebGUI
Figure 2-1 Change Password Screen
You should now see the MAIN MENU screen (see Figure 2-3).
Step 6.
The management session automatically times out when the time period set in the
Administrator Inactivity Timer field expires (default five minutes). Simply log back
Resetting the Contivity 221
2.3
If you forget your password or cannot access the SMT menu, you will need to reload the factory-
default configuration file or use the RESET button the back of the Contivity 221. Uploading this
configuration file replaces the current configuration file with the factory-default configuration file.
This means that you will lose all configurations that you had previously and the speed of the
console port will be reset to the default of 9600bps with 8 data bit, no parity, one stop bit and flow
control set to none. The password will be reset to "setup", also.
2.3.1
Procedure To Use The Reset Button
Step 1.
Press the RESET button for ten seconds, and then release it. The Contivity 221 restarts.
Otherwise, go to step 2.
Step 2.
Turn the Contivity 221 off.
Step 3.
While pressing the RESET button, turn the Contivity 221 on.
317517-A Rev 00
into the Contivity 221 if this happens to you.