Parameter
Click Apply.
4.
Section 5.4.10

Configuring the WIN and TIN Protocols

To configure the WIN or TIN protocols for a serial port, do the following:
1.
Make sure the serial port is configured to use either the WIN or TIN protocol. For more information, refer to
Section 5.4.5, "Configuring a Serial Port"
2.
Navigate to Serial Protocols » Configure Protocols » Configure WIN and TIN . The WIN and TIN form
appears.
13
Figure 92: WIN and TIN Form
1. TIN Mode Box    2. TIN Transport List    3. WIN Transport List    4. TIN IP Box    5. WIN IP Box    6. Messaging Aging Timer Box   
7. Address Aging Timer Box    8. Broadcast Addresses List    9. Unicast Addresses List    10. Link Stats Options    11. WIN DSCP Box   
12. TIN DSCP Box    13. Apply Button    14. Reload Button
3.
Configure the following parameter(s) as required:
Parameter
TIN Mode
Configuring the WIN and TIN Protocols
Description
Default:   0
To set the DS byte in the IP header. DS byte setting is supported in
the egress direction only.
.
Description
Synopsis:   1 to 2
Default:   1
The TIN Protocol running mode.