Chapter 5
Setup and Configuration
15
Figure 86: Protocol Form
1. Port Box    2. Pack Char Box    3. Pack Timer Box    4. Pack Size Box    5. Flow Control Options    6. Response Time Box   
7. Response Dest Options    8. Transport Options    9. Call Dir List    10. Max Conns Box    11. Loc Port Box    12. Rem Port Box    13. IP
Address Box    14. Link Stats Options    15. Apply Button    16. Reload Button
4.
Configure the following parameter(s) as required:
Parameter
Port
Pack Char
Pack Timer
Pack Size
144
Description
Synopsis:   1 to maximum port number
Default:   1
The port number as seen on the front plate silkscreen of the
switch.
Synopsis:   0 to 255 or { Off }
Default:   Off
The character that can be used to force forwarding of
accumulated data to the network. If a packetization character is
not configured, accumulated data will be forwarded based upon
the packetization timeout (Pack Timer) parameter.
Synopsis:   3 to 1000
Default:   10 ms
The delay from the last received character until when data is
forwarded.
Synopsis:   16 to 1400 or { Maximum }
Default:   Maximum
The maximum number of bytes received from the serial port to be
forwarded.
Configuring the Raw Socket Protocol
RUGGEDCOM ROS
User Guide