Figure 72: SNMP Access Form
1. Group Box    2. Security Model Box    3. Security Level Box    4. ReadViewName Box    5. WriteViewName Box    6. NotifyViewName
Box    7. Apply Button    8. Delete Button    9. Reload Button
3.
Configure the following parameter(s) as required:
Parameter
Group
SecurityModel
SecurityLevel
ReadViewName
WriteViewName
NotifyViewName
Adding an SNMP Group
8
Description
Synopsis:   Any 32 characters
The group name to which the security model and name belong.
This name is used as an index to the SNMPv3 VACM Access Table.
Synopsis:   { snmpV1, snmpV2c, snmpV3 }
Default:   snmpV3
In order to gain the access rights allowed by this entry, configured
security model must be in use.
Synopsis:   { noAuthNoPriv, authNoPriv, authPriv }
Default:   noAuthNoPriv
The minimum level of security reqwuired in order to gain
the access rights allowed by this entry. A security level of
noAuthNoPriv is less than authNoPriv, which is less than authPriv.
Synopsis:   { noView, V1Mib, allOfMib }
Default:   noView
This parameter identifies the MIB tree(s) to which this entry
authorizes read access. If the value is noView, then no read access
is granted.
Synopsis:   { noView, V1Mib, allOfMib }
Default:   noView
This parameter identifies the MIB tree(s) to which this entry
authorizes write access. If the value is noView, then no write
access is granted.
Synopsis:   { noView, V1Mib, allOfMib }
Default:   noView
This parameter identifies the MIB tree(s) to which this entry
authorizes access for notifications. If the value is noView, then no
access for notifications is granted.