Default passwords are configured for each user type initially. It is strongly recommended that these be changed
before the device is commissioned.
NOTE
Users can also be verified through a RADIUS or TACACS+ server. When enabled for authentication and
authorization, the RADIUS or TACACS+ server will be used in the absence of any local settings. For
more information about configuring a RADIUS or TACACS+ server, refer to
Authentication Server"
CAUTION!
To prevent unauthorized access to the device, make sure to change the default passwords for each
profile before commissioning the device.
To configure passwords for one or more of the user profiles, do the following:
Navigate to Administration » Configure Passwords . The Configure Passwords form appears.
1.
12
Figure 44: Configure Passwords Form
1. Auth Type Box    2. Guest Username Box    3. Guest Password Box    4. Confirm Guest Password Box    5. Operator Username Box   
6. Operator Password Box    7. Confirm Operator Password Box    8. Admin Username Box    9. Admin Password Box    10. Confirm
Admin Password Box    11. Password Minimum Length box    12. Apply Button    13. Reload Button
Configuring Passwords
Guest
û
û
û
.
User Type
Operator
ü
û
û
Section 4.8, "Managing an
Chapter 4
System Administration
Admin
ü
ü
ü