Managing The Configuration File; Configuring Data Encryption - Siemens RUGGEDCOM ROS User Manual

Hide thumbs Also See for RUGGEDCOM ROS:
Table of Contents

Advertisement

Chapter 4
System Administration
Message Name
MAC Address Authorization
Failure
Secure Port X Learned MAC Addr on VLAN X
RUGGEDCOM ROS logs a message in the syslog and sends a configuration change trap when a MAC address is
learned on a secure port. Port X indicates the secured port number and VLAN number on that port. This message is
not configurable in RUGGEDCOM ROS.
Message Name
Secure Port X Learned MAC Addr on VLAN X
Port Security Violated
This message is only applicable when the security mode for a port is set to "802.1X or 802.1X/MAC-Auth"
RUGGEDCOM ROS this alarm and logs a message in the syslog when the host connected to a secure port tries to
communicate using incorrect login credentials.
Message Name
802.1X Port X Authentication
Failure
802.1X Port X Authorized Addr.
XXX
Section 4.7

Managing the Configuration File

The device configuration file for RUGGEDCOM ROS is a single CSV (Comma-Separate Value) formatted ASCII text
file, named config.csv. It can be downloaded from the device to view, compare against other configuration
files, or store for backup purposes. It can also be overwritten by a complete or partial configuration file uploaded
to the device.
To prevent unauthorized access to the contents of the configuration file, the file can be encrypted and given a
password/passphrase key.
CONTENTS
Section 4.7.1, "Configuring Data Encryption"
Section 4.7.2, "Updating the Configuration File"
Section 4.7.1

Configuring Data Encryption

To encrypt the configuration file and protect it with a password/passphrase, do the following:
100
Alarm
Yes
SNMP Trap
Yes
Alarm
Yes
No
SNMP Trap
Yes
SNMP Trap
Yes
No
Managing the Configuration File
RUGGEDCOM ROS
User Guide
Syslog
Yes
Syslog
Yes
Syslog
Yes
Yes

Advertisement

Table of Contents
loading