Reference Stage Process - JDS Uniphase 4100 User Manual

Otdr modules for t-berd/mts-2000 and t-berd/mts-4000, handheld modular test set
Table of Contents

Advertisement

Chapter 8 FiberComplete Modules
Establishing References
Table 8
Reference methods for Insertion Loss and ORL Testing
IL Loopback
Reference Method
Setup
No specific require-
requirement
ment
Each unit is perform-
ing its own IL refer-
ence, with its source
Description
from the module port
and powermeter from
the base-unit, this with
one dedicated jumper.
Easiest process.
Not recommended for
short links.
One the reference is
Recommen
performed, do not dis-
dations
connect jumper from
the source
Link ORL, including
link connectors.
Loss
principle
Adapter
Reference
stage process
108
Reference methods for insertion loss and ORL testing
Adapter
Link under test
The Power Meter option is mandatory onto the Mainframe.
Each test equipment must set its own references and conform to the
following process:
R
1
ESULTS
Press
2
Press References > Take Refs keys and follow the step by step
instructions to perform references on each unit.
3
Choose between side by side or loopback for you loss referencing
method
User Manual
770000102/08
IL Side-by-side
Reference method
Units shall be at the same
location for references
Each unit is performing its
own IL reference, and
units are connected using
two jumpers and a bulk-
head adapter.
Most accurate setup, but
both units must be at the
same location for refer-
ences.
Once the reference is
performed, do not discon-
nect jumper from units
ports.
Link IL including one link
connector
Adapter
Adapter
Link under test
button
Zero ORL reference
method
No specific require-
ment
Each unit is perform-
ing its own ORL refer-
ence, with its source /
powermeter from the
module, this with one
dedicated jumper
Easy process.
Once the reference is
performed, do not dis-
connect jumper from
the source.
Use of non reflective
terminator is manda-
tory for bend insensi-
tive jumper.
Link ORL measure-
ment after jumper, for
optimized testing.
Requires mandrel
wrap or non reflective
termination at link
end.