Entering the Manual Mode

For programming, testing, and retrieving information
from the control, it is often necessary to enter the
Manual Mode by following the four simple steps below.
For an overview of entering the Manual Mode, refer to
the flowchart on the following page.
How to Enter the Manual Mode
1. If accessing Diagnostic Tests, be sure the washer
is in the Ready Mode before continuing to step 2.
If the washer is in an active cycle, rapid advance
through the cycle. Refer to Rapid Advance
Feature. If coins or a card has been entered, refer
to Clear Vend Feature.
2. Open the service door. Refer to Opening the
Service Door.
NOTE: The coin vault switch must be closed to
enter the Manual Mode.
3. While pressing and holding the NORMAL
keypad with one hand, press the HOT keypad
with the other hand.
4. The display will show "rAPd".
5. Press the DELICATES ( ) or the COLD ( )
keypad to scroll through the options until the
desired option appears in the display.
6. Press the START (enter) keypad.
NOTE: After entering Manual Mode, if no keypads
are pressed for 4.25 minutes, the control will return
to the previous mode of operation. If entering
Manual Mode while the washer is in an active
cycle, the machine will continue to run.
7. To exit, press the WARM (<) keypad. The control
will revert back to Ready Mode.
14
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
Manual Mode is broken into two groups: Manual
Programming and Manual Rapid Advance/Diagnostics.
Manual Programming can only be turned on or off
with an external device or a network. Refer to the
appropriate instruction manual. Manual Rapid
Advance/Diagnostics can be turned on and off using an
external device by manual programming (refer to
options 34 and 35 of Programming Control), or with
the network.
By default, both groups are turned "on".
The manual features available in each group are as
follows (the menu displayed on the display in this
mode is in parenthesis).
Manual Programming
Manual Programming (Prog)
Manual Read Audit (AUdt)
Manual Reset (rSEt)
Rapid Advance/Diagnostics
Rapid Advance (rAPd)
Diagnostic Tests (diAg)
If a group is turned off, the display will change from
the selected feature to "oFF", an audio signal will
sound for one second and the features in the group
cannot be entered. The display will then return to the
selected feature.
202065R6

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents